Digital Flow Meter with back-run stop
Flow meter with back-run stop for measuring water volume in vertical plankton net tows.
Explore product sections
About
The 23.091 Digital Flow Meter with back-run stop is used to determine the amount of water passing through a plankton net or a pipe. The back-run stop mechanism ensures the counter only records flow during upward or retrieval movement—ideal for vertical hauls. It features a 5-digit counter, a 70 mm propeller, and a 32 mm counter body. The unit’s free-flooding design allows operation at unlimited oceanographic depths. Water volume can be calculated using KC Denmark’s conversion spreadsheet for circular, square, or rectangular net shapes.
Features
Highlighted features for Digital Flow Meter with back-run stop
Specifications
Digital Flow Meter with back-run stop Specifications
- Model
- 23.091
- Propeller diameter
- 70 mm
- Counter body diameter
- 32 mm
- Length
- 185 mm
- Counter type
- 5-digit mechanical
- Flow meter read-out max value
- 99999
- Connection
- Triple point connection on nosepiece
- Design
- Free flooding, suitable for unlimited depth
Application
Recommended for vertical tows of plankton nets, ensuring accurate measurement by preventing counter activity during descent. Also suitable for use in pipes of known diameter.